| 1) Can a Figure 0544D be used with a water closet using a flush valve? | This is not recommended because the 0544D fitting does not have a cross over baffle to prevent waste blow through to the opposite toilet which could occur because of the flush velocity created by the flush valve. |
| 2) Do all Smith fixture supports meet their relative ANSI/ASME standard? | Yes, the supports are designed and built to meet or exceed the applicable strength and deflection criteria in the standard. Example for a water closet - 300 lb load, Type 1 urinal - 300 lb load, Type 1 lavatory - 300 lb load, etc. |
| 3) Is the M58 nipple available in lengths in excess of 10"? | Yes, but must be special made. |
| 4) What is the purpose of the lower plate assembly provided with the 0637 urinal support? | To provide a means for securing bearing studs which thrust against the lower portion of the urinal to prevent it from pressing against the finished wall. |
| 5) What weight will the water closet supports support? | All supports are designed to meet and /or exceed the ANSI/ASME Standard in regards to weight and deflection. Presently the standard requires water closet supports to support a minimum of 300 lbs. If the requirement to support 500 lbs. is specified, the rear anchor support should be utilized which will easily meet the 500 lbs. |