5810 and 5811 Non-Freeze Boxed Ground Hydrants
    5810F/5811F   5812/5813/5814    
Ground Hydrant with 3/4" (19) or 1" (25) Connections
FUNCTION: This non-freeze hydrant has a hinged covered box for positive protection against freezing when buried, outside or in an unheated area, and the closing valve is located below the frost line. When hydrant is shut off, water is drained from the casing through the drain hole in the valve housing. The hydrant is available with a 3/4” or 1” inlet connection. The locking cover prevents unauthorized use.
REGULARLY FURNISHED:
Bronze Non-Freeze Ground Hydrant with "T" Handle Key, and Bronze Hydrant Box. Inlet Size Furnished as Indicated by Figure Number Selected.

VARIATIONS:
1"(25) Hose Connection Adaptor -HC1
Less Drain Hole -LD
1/8" NPT Drain Hole in Box -N
1/8" NPT Drain Hole in Valve Housing -NV
Mild Climate -SAP
"Water" Cast on Cover -W
OPTIONAL MATERIALS:
Nickel Bronze Box -NB
Polished Bronze Box -PB
5810 and 5811 Non-Freeze Boxed Ground Hydrants

Related Links:

Ordering Guidelines

CSI Specifications

Replacement Parts for Ground Hydrants

Professional Grade Wall and Ground Hydrant Brochure

Product Features
• 3/4” or 1” inlet connection and 3/4” hose connection
• Removable “T” handle key
• Bronze hydrant and box
• Commercial and light commercial construction applications
NOTES:
  1. Recommended Box-out 5 3/4" (145) x 5 3/4" (145).
  2. All Jay R. Smith hydrants are manufactured with "NO-LEAD" brazing rings and USDA approved lubricants.



B(Depth of Bury) = 02" (610), 03" (915), 04" (1220), 05" (1525), 06" (1830), 07"(2135) or 08" (2438) Feet
*B = 9 1/2" (240) When Specified 5810-SAP
*B = 9 1/2" (240) When Specified 5811-SAP

 
5810 Drawing

 
Section Index
 

Go Back

   

List Price