| SANI-CEPTOR® USAGE | ||||||||||||||||
|
SANI-CEPTORS used as sanitary indirect waste receptors are required by modern plumbing codes in buildings where food is handled or processed such as restaurants, cafeterias, food markets and food processing plants. SANI-CEPTORS used as sanitary floor and area drains are essential in locations where human life could be endangered due to lack of sanitation such as hospitals, nursing and convalescent homes, clinic rooms and laboratories; also food processing plants such as dairies, creameries and breweries. These vital areas must be kept absolutely clean because the function which they serve is connected with the health and well-being of people. When sanitation, durability and longevity are considered, SANI-CEPTORS are the most cost effective drains for most applications. |
||||||||||||||||
HOW TO SELECT A "SANI-CEPTOR"®
|
||||||||||||||||
| SELECTION OF MATERIALS | ||||||||||||||||
|
Smith SANI-CEPTORS are constructed in two basic types: 1) 14 Gauge type 304 stainless steel -SS body, SS internal strainers and buckets, and SS or Nickel Bronze tops. 2) Heavy cast iron body with acid resistant coated (A.R.C.) interior, aluminum internal strainers and buckets and nickel bronze or A. R. C. tops. Stainless steel SANI-CEPTORS are seamless deep drawn and fabricated from 14 gauge type 304 stainless steel sheet. This heavy metal assures a rugged product. Type 304 SS is one of the most corrosion-resistant of the widely used stainless steels. For even greater corrosion resistance to certain chemicals, type 316 SS is offered as an optional material. In selecting the proper stainless steel for your particular application, please click here for corrosion resistance data. |
Strainers and Buckets for A.R.C. SANI-CEPTORS are furnished in light weight corrosion resistant aluminum because dropping a heavy cast iron strainer or bucket could chip or damage the coating causing almost irreparable damage. Stainless Steel SANI-CEPTORS are furnished with SS strainers and buckets. Since there is no coating to chip or damage, this potential problem is eliminated. |
|||||||||||||||
| SELECTION OF RECEPTOR BODY | ||||||||||||||||
|
The body size and depth are determined by the anticipated use. Where large flow rates are anticipated, bodies with greater capacity should be used. Where SANI-CEPTOR® drains are used for an indirect waste application, it is important to select a body with sufficient depth to prevent splashing. The need for a large capacity sediment bucket will necessitate the selection of a deep body. Round bodies are more easily cleaned than square bodies; however, all Smith square or rectangular bodies are designed with large radius corners to facilitate cleaning. |
||||||||||||||||
|
Following are body types, options and recommendations:
2) BODY WITH WIDE TOP FLANGE: Prefix DX stainless steel SANI-CEPTORS are designed for installation in wood decking over 16" C/C joists (Fig. 4). Top flange is 3/16" below drain rim and grate to accept standard thickness waterproof covering (A). Covering manufacturers require top of wide flange be installed approximately 1/8" below decking. This is accomplished automatically when using 3/4" plywood (C) which permits waterproof covering to be sloped (dimpled) toward drain grate (D). Drain flange is regularly provided with countersunk anchor holes for optional screws or bolts which can secure flange to deck. Wood screws furnished when specified (B).
|
These SANI-CEPTORS are also perfectly suited for installation in concrete floors and decks (Fig. 5). Anchor clips securely anchor the drain body into concrete (G). Optional anchor bolts, washers and nuts furnished when specified (F).
Optional screed guides set top flange approximately 1/8" below the concrete surface as required (E). See (A) above for details.
![]() Prefix DX cast iron SANI-CEPTORS are shown in this section. They are installed similar to other Prefix DX drains shown in Roof and Floor Drain Sections. 3) TRAP PRIMER CONNECTION: To indicate a trap primer connection on a Smith stainless steel SANI-CEPTOR® body, add Suffix -P to the figure number selected. Connection is located on vertical C/L 2" above bottom of drain (Fig. 6). These connections are not recommended for A.R.C. SANI-CEPTORS because the exposed pipe threads rust causing an objectionable discoloration on the A.R.C. wall. When a trap primer connection is needed for A.R.C. application, Smith recommends the use of Auxiliary Inlet Fitting Fig. 2697 (Fig. 7).
|
|||||||||||||||
| SELECTION OF INTERNAL STRAINERS AND BUCKETS | ||||||||||||||||
| Dome bottom strainers or buckets are regularly furnished as indicated by the figure number of the SANI-CEPTOR® selected. |
||||||||||||||||
|
||||||||||||||||
| SELECTION OF TOPS | ||||||||||||||||
|
TOP GRATES & COVERS FOR TRAFFIC AREAS
Solid covers prevent entry of foreign materials when the drain is out of service. They are ideal in locations where use may be intermittent, seasonal or where future use is anticipated. Solid covers may be replaced with a grate at any future time or, conversely, existing drain grates may be replaced with solid covers.
TOP GRATES & COVERS FOR NON-TRAFFIC AREAS
For applications where there is danger of someone stepping into the open top of the receptor, the Smith SANI-CEPTOR® line includes half grates (Fig. 14) and three-quarter grates (Fig. 15) and grates with center hole (Fig. 16). These allow the indirect waste to be discharged into the open portion, preventing splashing while protecting balance of the top area with grating.
|
Half grates (Fig. 17) are particularly suitable for installation beneath frozen food, fruit, vegetable and meat cases. They are installed with the half grate exposed in the toe space and the indirect waste half concealed beneath the case. Smith half grates are either secured or designed to be stable. The unique stabilizing leg (Fig. 14), for example, on A.R.C. half grates prevents the half grate from sliding out of place. Angle grates (Fig. 18) are a variation for modern restaurant designs that incorporate a curb which supports "off the floor" stools and service counter. Both installations provide a sanitary floor drain accessible from the aisle for cleaning by removing the exposed grate with the indirect waste half concealed by the case or counter.
Partial solid covers are available in place of half grates, three-quarter grates and grates with center hole. They should always be used in lieu of grates when the
indirect waste receptor will not be utilized as a floor drain, because they prevent the entry of foreign materials. Solid covers should also be used when the
velocity of the indirect waste flow is sufficient to cause splashing up through a grate.
The solid cover with center hole (Fig. 19) is particularly desirable when steam or hot water is being discharged with cabinetry installed overhead. This could
result in a water vapor which can cause dry rot and mildew in the cabinetry. The solid cover condenses the vapor within the receptor, greatly reducing the potential for damage. The use of these funnels with the Smith SANI-CEPTOR® prevents splashing of the discharged waste, allows the exposed portion of the grate to function as a floor drain and more importantly, retains the sanitary features of the SANI-CEPTOR®. To specify, simply refer to Optional Top Grates and Covers. Then select the suffix number for the grate shown with the funnel desired.
SHAPE OF TOP GRATES AND SOLID COVERS
|
|||||||||||||||
| SELECTION OF SPECIAL APPLICATION ITEMS | ||||||||||||||||
|
Dairy drains for quarry tile floors. Quarry tile is often chosen for use in dairies, creameries, breweries and similar food processing installations because of its smooth durable surface. Milk and brewery residue retained by rough surfaces, crevices and pockets common to "regular" floor drains will soon sour. This unsanitary condition fosters bacterial growth and creates undesirable odors. Special A.R.C. coated cast iron dairy drains are available for this service. See Fig. 3110 thru Fig. 3131. When equivalent stainless steel drains are required, please select the desired drain from 3000 or 3000-NB Series and specify the flange to be 3" down from top of drain which is required for quarry tile floors. Then add suffix numbers as desired for top grates or covers and suffix -SBP for solid bottom ported bucket. Water supply control boxes: Click here for the product page, are completely vandal proof and ideal to supply hot, cold or tempered water to can washing drains, flushing rim drains or other devices requiring a water supply. They are particularly recommended for installation with:
|
||||||||||||||||
|
|
|
|
|